Siemens Healthineers admin Ağustos 24, 2020

Siemens Healthineers

Line Sources – Siemens

Ge-68 line sources are double layered tubes and made of high quality stainless steel. Each line source is sealed on its ends by the process of precise argon welding. Thanks to the argon welding process, the possibility of activity leakage is eliminated, ensuring safe use of line sources.

Source related information including product code, isotope type, activity, serial number and production date is permanently marked with laser for traceability.

Uniformity

Each line source is tested with 5 mm steps of scannings throughout its length for uniformity.

The uniformity of the line sources is within +/- 5% limits.

GE-68 Cylindirical Phantom – Siemens

Ge-68 Cylindirical phantoms are used for 2D and 3D normalization and in test images of PET and PET-CT systems. Radioactive element is uniformly filled in the cylindrical cast. Each cylindrical phantom manufactured is checked with a PET-CT scanner to ensure high quality.

The results of quality control image files are available upon request.

Siemens Healthineers SolutionsProduct CodeProduct TypeIsotopeActivity QuantityReplacement Period*
System ModelSINON SI
BIOGRAPH
Initial Set-up & Annual ReplacementFNT1010PhantomGe-6844 MBq1.2 mCi11 Year
CBK1020Line SourceGe-6837 MBq1 mCi21 Year
TST1030Test TubeGe-685.5 kBq0.15 uCi11 Year
BIOGRAPH PICO
Initial Set-up & Annual ReplacementFNT1014PhantomGe-6874 MBq2 mCi11 Year
CBK1020Line SourceGe-6837 MBq1 mCi21 Year
TST1031Test TubeGe-6815 kBq0.15 uCi11 Year
BIOGRAPH TRUE V & mCT & Horizon
Initial Set-up & Annual ReplacementFNT1012Long PhantomGe-6874 MBq2 mCi11 Year
CBK1020Line SourceGe-6837 MBq1 mCi11 Year
TST1031Test TubeGe-6815 kBq0.41 uCi11 Year
Initial Set-up & Annual ReplacementFNT1013Long PhantomGe-6892.5 MBq2.51 mCi11 Year
CBK1020Line SourceGe-6846.25 MBq1.24 mCi11 Year
TST1031Test TubeGe-6815 kBq0.41 uCi11 Year
BIOGRAPH 450 Vision
Initial Set-up & Annual ReplacementFNT1012Long PhantomGe-6892.5 MBq2.51 mCi11 Year
CBK1020Line SourceGe-6846.25 MBq1.24 mCi11 Year
TST1031Test TubeGe-6815 kBq0.41 uCi11 Year
BIOGRAPH 600 Vision
Initial Set-up & Annual ReplacementFNT1015Long PhantomGe-68111 MBq311 Year
CBK1020Line SourceGe-6846.25 MBq1.24 mCi21 Year
TST1031Test TubeGe-6815 kBq0.41 uCi11 Year
BIOGRAPH mMR
Initial Set-up & Annual ReplacementFNT1015Long PhantomGe-68111 MBq3 mCi11 Year
CBK1025Line SourceGe-6855 MBq1.5 mCi41 Year
TST1031Test TubeGe-6815 kBq0.41 uCi11 Year
Intevo xSpect w/Peaking
Initial Set-up & Annual ReplacementSPT1290Spot-LineCo-57117 MBq3 mCi11 Year
SPT1291Spot PeakingCo-571.49 MBq40 uCi11 Year
Intevo Symbia
Initial Set-up & Annual ReplacementCBK1920Line SourceGd-153370 MBq10 mCi11 Year
CBK1220Line SourceCo-571.85 MBq50 uCi11 Year
REQUEST A CALL BACK
NEED A CONSULTANT ?

    We are committed to protecting your privacy. We will never collect information about you without your explicit consent.